CASE STUDIES

Hydrocarbon Refrigerant Gas Conversion

(From R22 to HC-22a)

2HP ACPU.html

2x 15HP WCPU.html

1HP Split Unit Air Connd.html

Hydrocarbon Scroll Chiller

90HP Water Cooled HC Scroll Chiller.html

Hypermizer Gen Load

MBJB Street Lighting.html

Hypermizer M

Hotel 3phase Induction Motor Pump.html

18nos x 1.5kW Exhaust Blower using 30kW Hypermizer M.html

22kW Condenser Water Pump.html

55kW Palm Oil Kernel Crusher/ Screw Press.html

Induction Lamp

200Watt Induction High bay.html

Other Project Ref.

Project Ref DIC Epoxy pdffile

Project Ref Drilmaco pdffile

Project Ref PGEO pdffile

Project Ref PUB Kota Tinggi pdffile

Project Ref Teleflex Medical pdffile

 

CO2 Emission from Various type of Fuel.


Fuel

Emission of CO2 (kg CO2/ kWh)

Coal

0.37

Gasoline

0.27

Diesel

0.24

Light Oil

0.26

Natural Gas, Methane

0.23

LPG

0.24

Bioenergy

0

**** CO2 Emission rate for Malaysia Electricity Production (Sources by PTM & other internet sources, year 2005)
CO2 Emission Coefficient = (0.62 x 0.23) + (0.28 x 0.37) + (0.02 x 0.24) + (0.01 x 0.26)
= 0.2536 kg CO2 / kWh

The results of the calculated baselines using ACM0002 are summarised as follows:

Peninsular Malaysia:    0.631  kg CO2/kWh (Year 2006)

West of Sabah:  0.647  kg CO2/kWh (Year 2006)

East of Sabah:  0.800 kg CO2/kWh (Year 2006)

Sarawak:  1.116  kg CO2/kWh (Year 2006)

All the information here is for educational purpose.

BTU/hr = 1.08 x cfm x Delta Temperature (Degree F)

RT = 500 x GPM x Delta Temp (Degree F)

CO2 Emmission Reduction Case Study

1.0. KRAFT FOODS MANUFACTURING SDN BHD

KraftFoodsACPU HC new installation and conversionHC Split UnitCeiling Cassette

Energy Savings Since Year 2010 until Today >>Details

1.1. Air Conditioner, Chiller, WCPU or ACPU - 15,094.00 kWh/ month saving & reducing 114,292kg CO2 Emission per year

2. YKK (M) SDN BHD

YKK ZipYKK WCPUYKK WCPU HC COnversionR22 converted to HC-22a

Energy Savings Since Year 2009 until Today >>Details

2.1. Air Conditioner, Chiller, WCPU or ACPU - 11,928.96 kWh/ month saving & reducing 90,326kg CO2 Emision per year

3. SDP MANUFACTURING SDN BHD

Energy Savings Since Year 2009 until Today >>Details

3.1. Air Conditioner, Chiller, WCPU or ACPU - 4,143.36 kWh/ month saving & reducing 31,374kg CO2 Emission per year

4. KUALITI ALAM SDN BHD

Inverter KAKualitiAlamKualiti Alam

Energy Savings Since Year 2009 until Today >>Details

4.1. Air Conditioner, Chiller, WCPU or ACPU - 7,438.08 kWh/ month saving & reducing 56,321kg CO2 Emission per year

4.2. Drum Handling Fan - 4,716.00 kWh/ month saving & reducing 35,710kg CO2 Emission per year

5. JB COCOA SDN BHD

Energy Savings Since Year 2009 until Today >>Details

5.1. Air Conditioner, Chiller, WCPU or ACPU (1st Phase)- 1,587.54 kWh/ month saving & reducing 12,021kg CO2 Emission per year

6. NATSTEEL HOLDINGS (SG) PTE. LTD.

7. TNT LOGISTICS (SG) PTE. LTD.

8. NETSHOP ENTERPRISE

Energy Savings Since Year 2009 until Today >>Details

8.1. Lighting -35kWh/ month saving & reducing 107kg CO2 Emision per year

9. EE GUAN CONSTRUCTION (M) SDN BHD (Office)

Energy Savings Since Year 2009 until Today >>Details

9.1. Air Conditioner, Chiller, WCPU or ACPU - 190.08kWh/ month saving & reducing 579kg CO2 Emission per year

10. JONCAN COMPOSITES SDN BHD

Energy Savings Since Year 2009 until Today >>Details

10.1. Air Conditioner, Chiller, WCPU or ACPU -98kWh/ month saving & reducing 298kg CO2 Emission per year

10.2. Lighting -52kWh/ month saving & reducing 158kg CO2 Emision per year

11. SINAR TM SDN BHD

Energy Savings Since Year 2009 until Today >>Details

11.1. Air Conditioner, Chiller, WCPU or ACPU (1st Phase)- 196.32 kWh/ month saving & reducing 597kg CO2 Emission per year

11.2. Lighting -49.92kWh/ month saving & reducing 152kg CO2 Emision per year

12. DGR PACKING & SUPPLY SDN BHD

Energy Savings Since Year 2009 until Today >>Details

12.1. Air Conditioner, Chiller, WCPU or ACPU -130kWh/ month saving & reducing 396kgCO2 Emission per year

13. KOK AUTO SERVICE (Car Workshop)

Energy Savings Since Year 2009 until Today >>Details

13.1. Lighting -60kWh/ month saving & reducing 183kg CO2 Emision per year

13.2. Power Quality Improvement - Successfully increasing the P.F. from 0.58 to 0.85 & Above.

14. SUNTEC ALARM SYSTEM & AUTOMATION

Energy Savings Since Year 2009 until Today >>Details

14.1. Air Conditioner, Chiller, WCPU or ACPU (1st Phase)- 223.52 kWh/ month saving & reducing 680kg CO2 Emission per year

14.2. Lighting -6.48kWh/ month saving & reducing 20kg CO2 Emision per year

SPECIALISE IN:

Energy Savings System, Mechanical & Electrical Engineering, Control Switch Board / DB/ SubDB and MSB, Power Electrical & Control Wiring Works.

GreenEarth

ENER-SAVE SDN BHD

30 & 30A, Jalan Perlaluan Besi 3, Taman Sri Putri, 81300 Skudai, Johor, Malaysia.

Tel: +607-557 2669,

Fax: +607-558 2669

E-Mail: sales@ener-save.biz

Bottom Margin

Powered by: Ener-Save Sdn Bhd Web Master Group | Home | Company Profile | Products | Past Experiences | Case Studies | Contact Us |

Copyright © 2015 All Rights Reserved